IEC 60297 PDF

IEC Dimensions of Mechanical Structures of the mm (19 in) Series Part 1: Panels and Racks. IEC Mechanical structures for electronic equipment – Dimensions of mechanical structures of the ,6 mm (19 in) series – Part Basic. IEC Dimensions of Mechanical Structures of the mm (19 Inch) Series Part 2: Cabinets and Pitches of Rack Structures.

Author: Zujas Nidal
Country: Rwanda
Language: English (Spanish)
Genre: Environment
Published (Last): 3 November 2005
Pages: 462
PDF File Size: 16.86 Mb
ePub File Size: 20.59 Mb
ISBN: 413-3-99540-924-9
Downloads: 21513
Price: Free* [*Free Regsitration Required]
Uploader: Gushura

George, Chassis Slide MechanismU.

IEC | IEC Webstore

A variety of airflow patterns can be found, including front intakes and rear exhausts, as well as side intakes and exhausts. The height of the electronic modules is also standardized as multiples of 1. Road cases are typically made from 660297 chloride PVC laminated plywood sides, joined by extruded aluminum edging, steel corners, handles and latches. Non-isolated cases simply mount inch mounting rails inside the case.

In other projects Wikimedia Commons. The earliest repeaters from were installed in ad-hoc fashion on shelves, in wooden boxes and cabinets. Bell Labs Technical Journal.

Computer enclosure Mechanical standards Server hardware. A difficulty with forced air fan cooling in rack equipment is that fans can fail due to age or dust. Many wall-mounted industrial equipment enclosures have inch rack rails to support mounting of equipment.

There are a multitude of specialty server racks including soundproof server racks, air conditioned server racks, NEMA rated, seismic rated, open frame, narrow, and even miniature inch racks for smaller applications. In contrast to the “inch world”, ETSI also defined the size of the rack enclosure: Byit was an established standard with holes tapped for screws with alternating spacings of 1.

  ALAN KAY DYNABOOK PDF

The ifc relay rack appears on page at the bottom of column 1.

For rack mounted computer servers, devices generally intake air on the front and exhaust on the rear. A standard inch server rack cabinet is typically 42u in height, 19 inches Slides or rails for computers and other data processing equipment such as disk arrays or routers often need to be purchased directly from the equipment manufacturer, as there is no standardization on such equipment’s thickness measurement from the side of the ifc to the equipment or means for mounting to the rail.

A key structural weakness of front-mounted support is the shear stress placed on the mounting rails and the leading edge of the equipment. For instance, most optical disc players will not work upside-down because the driving motor mechanism does not grip the disc.

The shape of small cases is maintained by the rack rails and the cover seal extrusions alone.

inch rack – Wikipedia

A blade server enclosure might require 10U. Low-wattage devices may not employ active cooling, but use only passive thermal radiation and convection to dissipate heat.

From Wikipedia, the free encyclopedia. As a result, 4-post racks have become common, with such racks featuring a mirrored pair of rear mounting posts.

19-inch rack

When rack rails are too thin to 60279, rivnuts or other threaded inserts can be used, and when the particular class of equipment to be mounted is known in advance, some of the holes can be omitted from the mounting rails. In the event of a nut being stripped out or a bolt breaking, the nut can be easily removed and replaced with a new one. All Wikipedia articles needing words, phrases or quotes attributed Wikipedia articles needing words, phrases or quotes attributed from November Commons category link is on Wikidata.

  BULIMIA I ANOREKSJA PDF

Nineteen-inch racks are ifc often used to house professional audio and video equipment, including amplifierseffects unitsinterfaces, headphone amplifiers, and even small scale audio mixers.

Open Rack is a mounting system designed by Facebook ‘s Open Compute Project that has the same outside dimensions as typical inch racks e.

Threaded mounting holes in racks where the equipment is frequently changed are problematic because the threads can be damaged or the mounting screws can break off; both problems render the mounting hole unusable. List of International Electrotechnical Commission standards.

A pair of rails is mounted directly onto the rack, and the equipment then slides into the rack along the rails, which support it. A inch rack is a ice frame or enclosure for mounting multiple electronic equipment modules. Rack-mountable equipment is usually designed to occupy some integer number of U.

Nineteen-inch racks in two-post or four-post form hold most equipment in modern data centersISP facilities, and professionally designed corporate server rooms. Ieec 2,granted Oct.

Two-post racks are most often used for telecommunication installations. This prevents circular airflows where hot exhaust air is recirculated idc an adjacent device and causes overheating.

Ina durable fiber reinforced plastic inch rackmount case was patented by ECS Composites and became widely used in military and commercial applications for electronic deployment and operation.